Help with proper way to install drywall at ceiling vent


Hello everyone. I’m in general construction and I’m trying my hand at bigger drywall jobs. I’m currently doing drywall in a basement and I’m trying to settle a argument as to what’s the proper way to install drywall at a fiber board hvac vent. I would think that you cut out the drywall to the outside diameter of the vent but the home owner is saying that he wants it cut to the inside diameter of the vent. So that the fiber board vent would sit on the inside of the drywall and you would only see the vent opening. This feels wrong to me but I want to check with some pros to get your take on this. This is the first time I’ve ever drywalled with fiber board vents. I’ll try to attach a photo for visual reference. Any help would be greatly appreciated. Thanks.
Attached Thumbnails
Help with proper way to install drywall at ceiling vent-6b9201a4-e787-4955-8d3f-3e532dd266a4_1571873683558.jpg  

Vintageheethen is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. DrywallTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 10-24-2019, 07:12 PM   #2
Master Mud Monkey
 
Shelwyn's Avatar
 
Trade: Drywall Finish
Join Date: Apr 2015
Location: South West Florida, USA
Posts: 146
Thanks: 71
Thanked 95 Times in 54 Posts
Default

Re: Help with proper way to install drywall at ceiling vent


Condensation will be a problem, make him sign away any right to a free repair because of moisture damage or whatever if you do it. He should buy the proper metal vent or whatever needs to go there instead.
Shelwyn is offline  
Old 11-12-2019, 12:00 PM   #3
Senior Member
 
endo_alley_revisited's Avatar
 
Trade: drywall
Join Date: Aug 2016
Posts: 440
Thanks: 5
Thanked 173 Times in 119 Posts
Default

Re: Help with proper way to install drywall at ceiling vent


How will the vent finish out? Is there a conventional screen cover that goes over the top of the drywall and vent? In that case your only constraint is to not make the cut out bigger than what the vent cover will allow. Or is it the modern "Trimless" variety that we are seeing a lot of lately? This kind of screen has an edge similar to drywall L-metal. It finishes out so that the cut edge of the drywall disappears for all extent and purpose. If this is the case, the cutout must be no larger than what the "mud flange" of the panel will cover.
endo_alley_revisited is offline  

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?

 

SEO by vBSEO 3.6.1